25 resultados para wavelength

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Raman microscopy, based upon the inelastic scattering (Raman) of light by molecular species, has been applied as a specific structural probe in a wide range of biomedical samples. The purpose of the present investigation was to assess the potential of the technique for spectral characterization of the porcine outer retina derived from the area centralis, which contains the highest proportion of cone:rod cell ratio in the pig retina. METHODS: Retinal cross-sections, immersion-fixed in 4% (w/v) PFA and cryoprotected, were placed on salinized slides and air-dried prior to direct Raman microscopic analysis at three excitation wavelengths, 785 nm, 633 nm, and 514 nm. RESULTS: Raman spectra of each of the photoreceptor inner and outer segments (PIS, POS) and of the outer nuclear layer (ONL) of the retina acquired at 785 nm were dominated by vibrational features characteristic of proteins and lipids. There was a clear difference between the inner and outer domains in the spectroscopic regions, amide I and III, known to be sensitive to protein conformation. The spectra recorded with 633 nm excitation mirrored those observed at 785 nm excitation for the amide I region, but with an additional pattern of bands in the spectra of the PIS region, attributed to cytochrome c. The same features were even more enhanced in spectra recorded with 514 nm excitation. A significant nucleotide contribution was observed in the spectra recorded for the ONL at all three excitation wavelengths. A Raman map was constructed of the major spectral components found in the retinal outer segments, as predicted by principal component analysis of the data acquired using 633 nm excitation. Comparison of the Raman map with its histological counterpart revealed a strong correlation between the two images. CONCLUSIONS: It has been demonstrated that Raman spectroscopy offers a unique insight into the biochemical composition of the light-sensing cells of the retina following the application of standard histological protocols. The present study points to the considerable promise of Raman microscopy as a component-specific probe of retinal tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we have conclusively proven that the "enhanced" optical transmission through a periodic array of sub-wavelength holes in metal films (Ebbessen's experiment) is the result of the array periodicity. This work has overturned the commonly accepted theory that the surface plasmons were responsible for the transmission enhancement. It was demonstrated that the reflectance, transmittance and frequency selectivity of the multilayered arrays can be efficiently modified by the aperture shapes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impedance and radiation pattern parameters of a lambda/2 quadrifilar helix antenna (QHA) with turn angles in the range 0 degrees to 235 degrees are analyzed. It is shown that by selecting the helix turn angle to satisfy the minimum bandwidth and beamwidth requirements, an improved electrical performance and a reduction in the physical size of the antenna is obtained. This is demonstrated by comparing the performance of a conventional half turn QHA with structures having a smaller pitch length. The computed results are validated by experimental data at L-band.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimental results are presented for the focusing capability of an active phase conjugating lens for a single and a dipole source pair and these are compared with predictions. In addition for a single source we illustrate the ability of the lens to project a null at the lens focus instead of a peak. A scheme is also presented such that when a source or pair of sources is imaged through an identical pair of passive scatterers located symmetrically about the lens that imaging with sub-wavelength resolution is possible. The rationale for the operation of the lens and aberrations observed due to its finite array size is discussed and is supported throughout by means of numerical simulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To determine the age-related change in the peripheral short-wavelength-sensitive (SWS) grating contrast sensitivity function (CSF), cut-off spatial frequency (acuity) and contrast sensitivity for both a detection and resolution task were measured at 8 degrees eccentricity under conditions of SWS-cone isolation for 51 subjects (19-72 years). The acuity for both the detection and resolution task declined with age, the detection acuity being significantly higher than the resolution acuity at all ages (p

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surface-enhanced Raman scattering (SERS) spectra from molecules adsorbed on the surface of vertically aligned gold nanorod arrays exhibit a variation in enhancement factor (EF) as a function of excitation wavelength that displays little correlation with the elastic optical properties of the surface. The key to understanding this lack of correlation and to obtaining agreement between experimental and calculated EF spectra lies with consideration of randomly distributed, sub-10 nm gaps between nanorods forming the substrate. Intense fields in these enhancement “hot spots” make a dominant contribution to the Raman scattering and have a very different spectral profile to that of the elastic optical response. Detailed modeling of the electric field enhancement at both excitation and scattering wavelengths was used to quantitatively predict both the spectral profile and the magnitude of the observed EF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fast and accurate analysis and synthesis technique for high-gain sub-wavelength 2-D Fabry-Perot leaky-wave antennas (LWA) consisting of two periodic metallodielectric arrays over a ground plane is presented. Full-wave method of moments (MoM) together with reciprocity is employed for the estimation of the near fields upon plane wave illumination and the extraction of the radiation patterns of the LWA. This yields a fast and rigorous tool for the characterisation of this type of antennas. A thorough convergence study for different antenna designs is presented and the operation principles of these antennas as well as the radiation characteristics are discussed. Moreover, design guidelines to tailor the antenna profile, the dimensions of the arrays as well as the antenna directivity and bandwidth are provided. A study on the radiation efficiency for antennas with different profiles is also presented and the trade off between directivity and radiation bandwidth is discussed. Numerical examples are given throughout to demonstrate the technique. A finite size antenna model is simulated using commercial software (CST Microstripes 2009) which validates the technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Theoretical emission-line ratios involving Fe xi transitions in the 257-407 A wavelength range are derived using fully relativistic calculations of radiative rates and electron impact excitation cross-sections. These are subsequently compared with both long wavelength channel Extreme-Ultraviolet Imaging Spectrometer (EIS) spectra from the Hinode satellite (covering 245-291 A) and first-order observations (similar to 235-449 A) obtained by the Solar Extreme-ultraviolet Research Telescope and Spectrograph (SERTS). The 266.39, 266.60 and 276.36 A lines of Fe xi are detected in two EIS spectra, confirming earlier identifications of these features, and 276.36 A is found to provide an electron density (N-e) diagnostic when ratioed against the 257.55 A transition. Agreement between theory and observation is found to be generally good for the SERTS data sets, with discrepancies normally being due to known line blends, while the 257.55 A feature is detected for the first time in SERTS spectra. The most useful Fe xi electron density diagnostic is found to be the 308.54/352.67 intensity ratio, which varies by a factor of 8.4 between N-e = 108 and 1011 cm-3, while showing little temperature sensitivity. However, the 349.04/352.67 ratio potentially provides a superior diagnostic, as it involves lines which are closer in wavelength, and varies by a factor of 14.7 between N-e = 108 and 1011 cm-3. Unfortunately, the 349.04 A line is relatively weak, and also blended with the second-order Fe x 174.52 A feature, unless the first-order instrument response is enhanced.